Functions |
Power / Energy / Position / Size |
Absorber Type |
Broadband |
Spectral Range |
0.19 - 20µm |
Aperture |
Ø50mm |
Power Mode |
Power Range |
150mW - 250W (b) |
Power Scales |
250W / 30W |
Power Noise Level |
15mW |
Maximum Average Power Density |
10kW/cm2 at 250W 12kW/cm2 at 150W |
Response Time with Meter (0-95%) typ. |
2.8s |
Calibration Uncertainty |
±1.9% |
Power Accuracy |
±3% |
Linearity with Power |
±1.5% |
Energy Mode |
Energy Range |
80mJ - 300J |
Energy Scales |
300J / 30J / 3J |
Minimum Energy |
80mJ |
Maximum Energy Density J/cm2 |
|
<100ns |
0.3 |
1µs |
0.4 |
0.5ms |
5 |
2ms |
10 |
10ms |
30 |
Beam Tracking Mode |
Position |
|
Beam Position Accuracy |
0.2mm + 5% of distance from center (c) |
Beam Position Resolution |
0.1mm |
Min Power for Position Measurement |
2W |
Size (d) |
|
Size Accuracy mm (e) |
±5% for centered beam |
Size Range (4σ beam diameter) |
Ø5-35mm |
Min Power Density for Size Measurement |
3W/cm² |
Cooling |
Fan |
Minimum Water Flow Rate at Full Power |
NA |
Fiber Adapter Available |
ST, FC, SMA, SC |
Weight |
0.9Kg |
Part number |
7Z07902 |
Notes: (a) The BeamTrack features are supported by Centauri, StarBright, StarLite, Nova II and Vega meters, Juno, Juno+ and EA-1 interfaces and StarLab application. Position and Size measurements work only in Power mode (but not in single shot Energy mode). (b) For powers up to 30W it is recommended to work with the fan off and then the noise level is ~3 times lower. It is also recommended to measure energy with the fan off. (c) Position accuracy for the central 20mm of the aperture as limited by beam position resolution. Position can be tracked with ±1mm accuracy over central 32mm of the aperture. Accuracy is reduced by a factor of 3 at minimum power. Position measuring center corresponds to geometrical center within <1mm. Position center can be software reset to geometric center or other desired position with Centauri, StarBright or StarLab. (d) Assumes laser beam with Gaussian (TEM00) distribution. For other modes, size measurement is relative. (e) Accuracy spec will be maintained for beams from 6 to 35mm not deviating from center more than 15% of beam diameter. (f) Calibrated for ~0.8μm, 1.064μm and 10.6μm (g) Water temperature range 18-30°C, Water temperature rate of change <1°C/min. Pressure drop across sensor 0.03MPa. (h) Position accuracy for the central 10 mm of the aperture as limited by beam position resolution. Position measuring center corresponds to geometrical center within <1mm. Position center can be software reset to geometric center or other desired position with Centauri, StarBright or StarLab. |