Rhea Series

Model : Rhea Series

Description :

Admesy’s Rhea is the new flexible platform in configurable spectral measurement demands within the range between 200 and 1100nm. Various choices in slit size, gratings and sensors allow you to build the perfect spectral measurement solution for your specific high-end measurement application or OEM integration. The Rhea series is available in a variety of optical systems: 5, 10 or 20mm collimating lenses, cosine corrector and fibre connectors. This flexibility makes the Rhea the ultimate high-end spectroradiometer for OEM integration, display, lighting and appearance measurements in both laboratory and production settings.

Highlights
• Configurable slit, grating and sensor to support various measurement applications between 200-1100nm
• Extreme sensitivity
• Cooled high-end CCD detector, cooled to -10 degrees Celsius
• High optical throughput design
• Neutral density filter wheel for huge dynamic range
• Built-in shutter function
• Low noise
• Auto-range function
• Very low stray light
• Excellent linearity, internally compensated within 1%
• Dark current compensated, virtually zero over entire integration range
• USBTMC compliant, SCPI command set, high speed device
• USB, RS 232, Ethernet connections and trigger in & out for ideal system and OEM integration
• Various calculations are carried out inside the device, saving processing power in production environments
• Robust housing, optimized for mounting and protection in harsh production environments
Specification

General specification

Non-linearity <1%
Data output resolution Selectable 0.5nm, 1nm, 2.5nm, 5nm or 10nm
Focal length 115mm
NA optical bench 0.1
Spectral range See spectral ranges and FWHM
Order sorting filter Linear variable filter
Wavelength accuracy +/- 0.5nm
Stray light <0.05% (measured @ 400nm with 455nm cut-off filter with broadband light source)
Luminance accuracy +/-2% (after calibration, compared to cal source)
Chromaticity accuracy +/-  0.0015  (after  calibration, compared to  cal source)
Detector High end Hamamatsu cooled detector (S7031)
Dark noise (RMS) ~ 3 to 5 counts (16 bit ADC)
S/N* >1300:1
Filter wheel OD1,   OD2,   OD3,   OD4,   open   and   shutter function
Integration time 4.8ms – 60minutes
Cooling temperature -10°C
Interfaces High  speed  USB,  RS232,  Ethernet,  Trigger connections
Measurement parameters Spectral output, radiometric data or colour data (Lumen, x,y, DWL, PWL, CRI, CCT, etc.)
Data processing time 15ms
Size (LxWxH) 230 x 195 x 82.5mm (without optical system)
Weight 3.3kg
Operating temperature 10-35°C
Power input Typical 15V DC (14.5-15.5V DC range)
Power consumption Typical 12W. Max 30W
Fibre connection SMA or M8

     Data Sheet